1. Electrical safety knowledge and precautions:
1. Electrical parameters of the retractable door: rated voltage AC 220V, frequency 50Hz, power: ≤1KW
2. Power lead: power lead within 50 meters, power lead above 50 meters 2≥0.75 ≥22.5
3. When the retractable door motor is running, ensure that the power supply voltage is not less than 200V. If it is lower than 200V, it will affect the stability of the retractable door or fail to work normally. At the same time, pay attention to the length and diameter of the wire.
4. The joints of the wires should be handled well, and pay attention to waterproofing to prevent leakage and short circuit.
5. Prevent the wrong connection of the 380V power source and the poor contact of the neutral wire, which will cause the live wire to form a high voltage 380V, which is easy to burn out the electrical products.
6. In order to prevent electric shock and leakage and ensure safety, grounding is required. The ground wire can be buried to the ground at the end of the door row for separate grounding, or it can share the ground wire with the power grid. The desktop power plug has a grounding plug.
2. Installation procedure:
1. The salesman contacts the customer for installation matters (determine the requirements of the ground, power supply, etc.)
2. Check whether the ground meets the requirements of electric door installation
3. Install track or limit magnet
4. Install the electric door to test and clean the door body
5. Invite customers for acceptance
6. Clean up the scene
Third, the track installation specification requirements:
1. Before installing the retractable door, first check whether the user's ground meets the installation conditions. 1) When installing a full trackless door, the ground requires every point to be level and there should be no unevenness, otherwise it will affect the operation of the electric door. There are track telescopic doors to reduce the requirements accordingly, but the error cannot exceed 0.5 cm, otherwise it will affect The operation of the gate row; the method of leveling the ground:
2. When installing the full trackless electric door, the magnet is installed in accordance with the attached magnet pre-embedding method, and the installation size cannot be changed at will to reduce the trouble of debugging.
3. When burying ground cement or tracks, please cover the cables with insulating pipes (PVC pipes) and pre-bury them in the ground together. Pay attention that there is no interface in the middle to avoid troublesome maintenance in the future. The wire diameter is required to be more than 0.75 square meters. The longer the buried wire, the larger the wire diameter.
Four, electric retractable door installation process
1. Check whether the ground meets the installation requirements;
2. Measure the size and find the center point of the ground track (when the user has a doorpost, consult the user for the installation location). Generally, the center of the doorpost is the reference point. If there is no doorpost, please ask the user for the installation location;
3. Use a woodworking ink fountain to eject the center line to establish the installation size.
5. Installation of electric retractable door track
Installation of trackless doors
1. When installing the trackless, measure the size on the center line according to the installation size of the magnet, and make the marking line;
2. Use a small percussion drill bit to make the positioning hole (be careful not to miss it);
3. After drilling the positioning hole, use the magnet with the same number to increase the hole position and deepen it to a height slightly deeper than the magnet;
4. Put water in the hole first, and then fill it with cement;
5. Put the magnets in sequence according to the same consistency (the magnets are level with the ground, can not be higher than the ground, remove the excess cement).
Installation of rail doors
1. Measure the position of the double track on both sides of the center line (single track is based on the center line). Refer to the attached electric door track installation method for the installation dimensions.
2. Use the ink fountain to eject the double track track line (single track is subject to the center line)
3. Use a floor laying machine to open the ground to the depth of the embedded track (according to the installation dimension drawing or customer requirements)
4. Put it into the track and fix the edge with a blast screw, and weld it with a welder (note that the plane of the track must not be bent or deformed.)
5. Fill the edge of the track with cement sand. (The corner wheel rail is first filled with cement sand in the corner iron and then fixed)
6. When pre-burying the track without ground, pay attention to the level of the track and the track on both sides (the track wheel needs to reserve the walking groove on both sides of the track).
7. The installation method and size diagram of the magnet after the reference of the limit magnet installation management.
8. Discharge the door into the track (for electric doors with a windproof card, remove the windproof card first, and then discharge the door into the track before reinstalling). Push the door row by hand, and check whether the door row has a card bottom beam to run out of the track. phenomenon,
Scan the QR code to read on your phone
CONTACT
Phone:+86 19182170296
Add:No. 63-69, Section 2, Huajin Avenue, Qingbaijiang District, Chengdu
E-mail:sales@cdjy1.cn
Web:en.cdjy1.cn
Copyright © 2020 Chengdu Jieying Intelligent Technology Co., Ltd.